TechOnTip Weblog

Run book for Technocrats

Archive for November, 2015

Change Exchange 2013 Transport Database Path

Posted by Brajesh Panda on November 25, 2015

è Open Exchange Shell as Administrator

è cd $exscripts

è Determine the new Log drive’s Drive letter & change drive letters in below script. Here I consider “L” drive is my new location. I always prefer to keep the same folder path as it is in C drive.

.\Move-TransportDatabase.ps1 –queueDatabasePath "L:\Program Files\Microsoft\Exchange Server\V15\TransportRoles\data\Queue" –queueDatabaseLoggingPath "L:\Program Files\Microsoft\Exchange Server\V15\TransportRoles\data\Queue" –iPFilterDatabasePath "L:\Program Files\Microsoft\Exchange Server\V15\TransportRoles\data\IpFilter" –iPFilterDatabaseLoggingPath "L:\Program Files\Microsoft\Exchange Server\V15\TransportRoles\data\IpFilter" –temporaryStoragePath "L:\Program Files\Microsoft\Exchange Server\V15\TransportRoles\data\Temp"

Cheers

Advertisements

Posted in Mix & Match | Leave a Comment »

Dell Hardware Info thru Powershell

Posted by Brajesh Panda on November 13, 2015

http://en.community.dell.com/techcenter/os-applications/w/wiki/4145.agentless-management-with-powershell-3-0-cim-cmdlets-and-idraclifecycle-controller?utm_content=buffere803b&utm_medium=social&utm_source=twitter.com&utm_campaign=buffer

Posted in Dell OEM, Mix & Match, Powershell | Tagged: | Leave a Comment »

 